Item |
Equipment Description |
Uses |
| 1 |
Infrared Camera: Therma
cam P65: Make: Flir System
Therma cam Reporter 7.0 professional and
software |
Infrared diagnosis of
equipment to locate hot spots and
temperature rise. Thus minimizing the risk
of failure and to plan a state oriented
maintenance |
| 2 |
SF6 Gas leak detector
3-033-R002
SF6 Volume % Measurement |
For the detection of
decomposition products sulphur dioxide SO2
and hydrogen fluoride HF being caused by
electric arcs in SF6-gas/ existing oil moist
can be determined as well |
| 3 |
Secondary Injection Tester
Type PTE 100C |
For secondary testing of
protective relay equipment such as:
Overcurrent relays, inverse time overcurrent
relays, undercurrent relays, ground fault
relays, directional overcurrent relays,
directional ground fault relays, overvoltage
relays, undervoltage relays, directional
voltage relays, directional power relays,
power factor relays, differential protection
(differential circuits), distance protection
equipment (phase by phase), negative
sequence overcurrent relays, motor overload
protection, automatic reclosing devices,
tripping relays, voltage regulating relays,
over impedance relays, Z >, under impedance
relays, Z, Thermal relays, time-delay
relays. |
| 4 |
Primary Current Tester
Type LET –1000-RD
|
For primary injection
testing of protective relay equipment and
circuit breakers. It is also used to test
the transformation ratio of current
transformers and other applications that
require high variable currents.
Specific applications: circuit breaker
testing, testing current transformers,
polarity testing, heat runs, automatic
reclosers and sectionalizers, testing
integrity of ground grids and safety-ground
devices. |
| 5 |
Digital Multimeter
Type Fluke175 |
Measurement or Testing for
the following; AC/DC voltage and current,
Resistance frequency temperature diodes,
continuity, capacitance |
| 6 |
Current Clamp (i400)
Type Fluke AC400A |
Measurement for AC current
and input impedance of <10W |
| 7 |
Temperature Probe
Type Fluke 80T-150U |
Measurement temperature of
air, surface and non-corrosive liquid. |
| 8 |
Digital Multimeter Type Fluke FL 87-5 |
Measurement or Testing
for the following; AC/DC voltage and
current, resistance, frequency, temperature,
diodes, capacitance and continuity. |
| 9 |
AC/DC Clamp
Type Fluke LEM LH 2040 |
Measurement or testing
for the following: AC/DC voltage and
current, Resistance, Diode. |
| 10 |
Digital Multimeter
Type Fluke FL187 |
Measurement or Testing
for the following; AC/DC voltage and
current, resistance, frequency, temperature,
conductance. |
| 11 |
Insulation tester
Type METRISO 5000A from GMC |
This instrument is suited
for non-destructive measurement of
insulation resistance in electrical systems,
at machines and transformers and in cables,
as well as within the electrical equipment
of locomotives, tram systems and ocean going
vessels, with eight selectable test voltages
up to 5kV. |
|
|